Tankless water heater installation cost dataset
This is the complete dataset behind the tankless calculator, at national wage rates. It prices a conversion rather than an appliance swap, so the lines that matter are the ones a storage tank never needed: a bigger gas pipe, a sealed flue of its own, a dedicated electrical circuit and a condensate drain. The appliance is sized here from flow and incoming water temperature rather than from the tank it replaces. Last reviewed 2026-08-23.
Sizing: flow, temperature rise and output
BTU/h = gallons per minute × 500 × temperature rise, working to an outlet temperature of 110 °F. The 500 is a gallon of water weighing 8.33 pounds times sixty minutes; a BTU raises one pound of water by one degree. This is arithmetic, not an estimate. What is estimated, and declared, is the incoming water temperature of each band.
| Flow | 40 °F in | 55 °F in | 70 °F in |
|---|---|---|---|
| 4 gpm — A shower and a sink at the same time | 140,000 | 110,000 | 80,000 |
| 7 gpm — Two showers plus a kitchen sink | 245,000 | 192,500 | 140,000 |
| 2.5 gpm — One shower on its own | 87,500 | 68,750 | 50,000 |
| 5.5 gpm — Two showers, or a shower and a bath filling | 192,500 | 151,250 | 110,000 |
⚠️ Read that table across, not down. The same flow needs 75% more heat in the north than in the south, and the incoming temperature is a winter figure rather than an annual average. Commercial units are made at 120,000, 150,000, 180,000, 199,000 BTU/h of input, and the model picks the smallest one that covers the requirement after efficiency — it does not round up a size for comfort, because that is a real cost and somebody should choose it knowingly.
Cost by flow and by climate
| Flow | Unit | Cost |
|---|---|---|
| 2.5 gpm | 120,000 | $4,001 |
| 4 gpm | 120,000 | $4,001 |
| 5.5 gpm | 180,000 | $4,631 |
| 7 gpm | 199,000 | $4,831 |
| Incoming water | Rise | Cost |
|---|---|---|
| 40 °F | 70 °F | $4,316 |
| 55 °F | 55 °F | $4,001 |
| 70 °F | 40 °F | $4,001 |
The gas pipe, the flue and the fuel
| Option | Cost |
|---|---|
| The existing gas pipe is big enough | $3,260 |
| Upsize the branch to the heater | $4,001 |
| New line all the way from the meter | $4,502 |
| Out through a nearby wall | $4,001 |
| Up and out through the roof | $4,187 |
| Natural gas | $4,001 |
| Propane | $4,196 |
| Electric | $4,291 |
⚠️ The gas pipe is the single largest uncontrolled variable: $1,241 between reusing the existing pipe and running a new one from the meter. It is decided by a survey, not by a phone call, and it is the item most often missing when a price is quoted before anybody has visited. The reason is in the product definition: 10 CFR 430.32(d) puts this class above 50,000 BTU/h, while the domestic tank being removed draws around 40,000.
Against replacing the tank with a tank
| What you do | Cost |
|---|---|
| Another storage tank | $1,772 |
| Convert to tankless | $4,001 |
226% of a tank swap. The tank side comes from our water heater dataset at the same national wage, which is the only reason the ratio is worth quoting. ⚠️ Neither figure contains a running cost, and this site will not publish one: what a conversion saves afterwards depends on local gas and electricity prices and on household hot water use, and none of the three is national or stable.
Line items
74% of the reference total comes from estimated rather than official figures. The reference job is a 4 gpm condensing gas unit replacing a gas storage tank in a mixed climate: a 55 °F rise, 110,000 BTU/h of output, a 120,000 BTU/h appliance and 17 trade hours.
| Line item | Unit | Material | Equipment / hr | Trade | Data |
|---|---|---|---|---|---|
| Non-condensing gas tankless heaterinput BTU ÷ 1,000, non-condensing | 1,000 BTU/h input | $5.50 – $10 | — | — | estimated±29% |
| Condensing gas tankless heaterinput BTU ÷ 1,000, condensing | 1,000 BTU/h input | $7.50 – $14 | — | — | estimated±29% |
| Electric tankless heaterkilowatts required | kW | $38 – $78 | — | — | estimated±34% |
| Upsized natural gas pipe and fittingsfeet of new gas pipe, 1.6× when run from the meter | linear ft | $12 – $30 | — | — | estimated±43% |
| Upsized propane pipe and fittingsfeet of new propane pipe, 1.6× when run from the meter | linear ft | $9.00 – $23 | — | — | estimated±44% |
| Second-stage propane regulator and tank connection1 on propane | each | $180 – $460 | — | — | estimated±44% |
| Gas fitting, pressure test and purge1.5, 5 or 8 hours depending on how much gas pipe is run | hour | — | — | Plumbers, Pipefitters, and Steamfitters | sourced |
| Sealed plastic intake and exhaust1 on a condensing unit | each | $140 – $380 | — | — | estimated±46% |
| Stainless category III venting1 on a non-condensing unit | each | $320 – $850 | — | — | estimated±45% |
| Running the vent and making the penetration3 hours through a wall, 6 through the roof | hour | — | — | Plumbers, Pipefitters, and Steamfitters | sourced |
| Condensate drain and neutraliser1 on a condensing unit | each | $60 – $180 | — | — | estimated±50% |
| Water connections and pressure relief1 per installation | each | $90 – $240 | — | — | estimated±45% |
| Isolation valves for descaling1 when service valves are fitted | each | $70 – $190 | — | — | estimated±46% |
| Dedicated circuit for the heater1 on a gas unit with a dedicated circuit | each | $70 – $200 | — | — | estimated±48% |
| Feeders and breakers for an electric tankless1 on an electric unit | each | $420 – $1,400 | — | — | estimated±54% |
| Electrical work2 hours on a gas unit, 7 on an electric one | hour | — | — | Electricians | sourced |
| Removal, mounting and commissioning7 trade hours, 5 when there is no old tank to remove | hour | — | — | Plumbers, Pipefitters, and Steamfitters | sourced |
| Disconnect and make safe the old 240 V circuit1.5 hours when an electric tank is being replaced | hour | — | — | Electricians | sourced |
| Old tank removal and disposal1 when the old tank is taken away | each | $45 – $130 | — | — | estimated±49% |
| Plumbing, gas and mechanical permits1 when the job is permitted | each | $120 – $420 | — | — | estimated±56% |
The reasoning behind each figure
- Non-condensing gas tankless heaterestimated, ±29%
- Priced per thousand BTU of input, so a 180,000 BTU/h unit lands around $990 to $1,800 for the appliance alone.
- Cheaper to buy and dearer to vent: the exhaust leaves hot, so it needs stainless category III pipe rather than plastic, and that pipe costs several times what plastic does per foot. On a long run the saving disappears entirely.
- Condensing gas tankless heaterestimated, ±29%
- Around a third more per thousand BTU than the non-condensing unit, and it usually comes back on the venting: a condensing heater exhausts cool enough for plastic pipe.
- It also produces mildly acidic condensate that needs a drain and, ideally, a neutraliser. That is a line rather than a footnote.
- Federal minimum for this class is a uniform energy factor of 0.81 under 10 CFR 430.32(d); a good condensing unit is well above it.
- Electric tankless heaterestimated, ±34%
- Priced per kilowatt of element capacity. The appliance itself is markedly cheaper than a gas one — there is no burner, no heat exchanger and no flue.
- ⚠️ Everything that is saved on the appliance is spent on the electrical supply, and frequently much more than that. This calculator works out the amperage required rather than assuming a unit size, because that number is what decides whether the project is possible at all.
- Upsized natural gas pipe and fittingsestimated, ±43%
- Priced by the foot of new pipe. The diameter comes from the flow the appliance needs and the length of the run, and both matter: the same heater needs a fatter pipe at fifty feet than at fifteen.
- ⚠️ This is the line that converts a $2,500 appliance into a $5,000 project, and it is the line a phone quote cannot possibly know about. A gas storage tank draws around 40,000 BTU/h. A tankless is above 50,000 by federal definition and is typically three to five times the tank.
- Upsized propane pipe and fittingsestimated, ±44%
- Cheaper per foot than natural gas for the same appliance, and not by a margin anyone should be surprised by: propane carries roughly two and a half times the energy per cubic foot, so the same heat travels through a smaller pipe.
- ⚠️ The saving is real and it is also smaller than what propane adds back on the regulator, so a propane conversion usually lands dearer overall than a natural gas one. The lines are kept separate here so you can see both halves rather than a net figure.
- Second-stage propane regulator and tank connectionestimated, ±44%
- A tankless is the largest single draw most propane houses have, and the existing regulator is very often sized for a range and a dryer rather than for this. Sizing it for the peak draw is the difference between a heater that works and one that drops out halfway through a shower.
- ⚠️ Assumes a tank is already there. If it is not, the tank, its pad and its setback from the house are a separate job with its own permit, and no part of it is priced on this page.
- Gas fitting, pressure test and purge
- Five hours to run the pipe, make the connections, pressure-test the system and purge it, and eight when the run comes all the way from the meter.
- Also includes verifying that the whole system still works: adding this load can starve a furnace or a range at the far end of the same pipe, and that is checked rather than assumed.
- Sealed plastic intake and exhaustestimated, ±46%
- Two pipes: a condensing heater draws its combustion air from outside and pushes the exhaust back out, both sealed, both in plastic.
- ⚠️ It cannot use the old chimney. A tankless heater has a fan and a sealed combustion chamber, and the masonry flue the tank vented into is neither the right size nor the right kind of thing.
- Stainless category III ventingestimated, ±45%
- A non-condensing heater exhausts too hot for plastic, so the vent is sealed stainless — several times the price per foot.
- This is why the cheaper appliance is frequently the dearer installation, and why the choice between condensing and not is really a choice about the vent rather than about efficiency.
- Running the vent and making the penetration
- Three hours out through a nearby wall; six up through the roof, where the penetration has to be flashed so that it stays watertight for the life of the roof.
- The termination point is not free choice: it has to clear windows, air intakes and walkways, and finding a legal one is occasionally what dictates where the heater goes.
- Condensate drain and neutraliserestimated, ±50%
- A condensing heater makes mildly acidic water whenever it runs. The neutraliser is a canister of limestone chips in the drain line: cheap, frequently skipped, and skipping it is what eats a cast iron waste stack from the inside.
- Where there is no drain below the appliance this becomes a pump as well, which is a moving part in an otherwise static installation.
- Water connections and pressure reliefestimated, ±45%
- Reconnecting the hot and cold sides to a wall-hung unit that is rarely where the tank stood, plus the relief valve and its discharge.
- A tankless is physically much smaller than a tank, so the pipework almost always has to be extended or re-routed even when the heater stays in the same room.
- Isolation valves for descalingestimated, ±46%
- A pair of service valves with hose ports, which is what lets the heater be flushed with descaling solution without cutting anything.
- ⚠️ Not optional in the way it looks. A tankless heater passes all your water across a narrow heat exchanger, so scale builds where it does most harm. In hard water it wants doing annually, and a unit fitted without these valves means paying a plumber to cut pipes every time. It is the cheapest line here and the one that decides the appliance’s life.
- Dedicated circuit for the heaterestimated, ±48%
- Even a gas tankless needs mains power: it has a fan, an igniter and a control board, and it wants its own circuit rather than sharing.
- A gas storage tank often needs no electricity at all, which is why this line surprises people converting from one. It is also why a gas tankless stops working in a power cut and a standing-pilot tank does not.
- Feeders and breakers for an electric tanklessestimated, ±54%
- Multiple heavy feeders — a whole-house electric tankless is normally fed by two or three separate double-pole breakers rather than one.
- ⚠️ This band assumes the panel has both the space and the capacity, which at these currents is a very strong assumption. Where it does not, a service upgrade is a separate job on our electrical panel page, and it is frequently larger than everything on this one.
- Electrical work
- Two hours for a gas unit’s dedicated circuit; seven for the multiple heavy feeders an electric one needs.
- Removal, mounting and commissioning
- Seven hours: drain and remove the old tank, mount the new unit on the wall, connect it, fire it and set the temperature.
- Draining a full tank is slower than it sounds and a sixty-gallon tank full of sediment is heavy and awkward on a basement staircase.
- Disconnect and make safe the old 240 V circuit
- An hour and a half. Coming off an electric tank leaves a 30 amp circuit feeding nothing: it is disconnected at the panel, the breaker comes out and the cable is capped or pulled back.
- Small money and worth naming, because a live cable ending in a junction box behind an appliance that is no longer there is exactly what an inspector looks for. The upside is a freed breaker space, which matters if the panel is full.
- Old tank removal and disposalestimated, ±49%
- Tipping fee less the scrap value of the steel, which is why the bottom of the band is low.
- Plumbing, gas and mechanical permitsestimated, ±56%
- Frequently more than one permit here, because the job touches gas, water, venting and electrics.
- The inspection is also the only independent check on a new gas line and a new flue, which on a combustion appliance inside a house is not a formality.
Not included in this dataset
- An electrical service upgrade
- Every figure assumes the panel has room and capacity. For an electric tankless at these currents that is a strong assumption, and where it fails the upgrade is priced on our electrical panel page and is often larger than this whole job.
- A larger gas meter
- If the meter itself cannot deliver the total load, the utility replaces it, on their schedule and sometimes with their own charge. Worth one phone call before collecting quotes.
- A water softener
- In hard water a softener extends the life of a tankless heater considerably, and it is a separate appliance with its own price. It is on our water softener page.
- A recirculation loop
- The pump and return pipe that make hot water arrive quickly at a distant tap. Frequently wanted alongside a tankless and priced separately, because in an existing house the return pipe is the expensive part.
- Annual descaling
- Not in the figure and not optional in hard water. The isolation valves priced here are what make it a cheap job rather than an expensive one.
- A like-for-like tank replacement
- If you are replacing a tank with a tank, this is the wrong page — that is priced on our water heater page, and it is a fraction of anything here.
Use the calculator, price a storage tank instead, or read the full method.